: FEATURES
- 4 metres spiral cable
- Electrical protection against back-emf
- Rubber over-moulding for shock protection and grip
- Stowage on cradle
- Operation in parallel with all AutoAnchor products eg toggle
switches, foot switches or other control equipment
- Connect to DC, AC and hydraulic systems
- Rugged cable and connectors with
- Moulded plug and socket rated to IP67
- 2m flying lead from socket for better connectivity
- Gold plated contacts on plug and socket to reduce
corrosion
- Socket sealing cap
: PLUS Windlass Control with Chain Counter
- Present the length of rode to deploy
- Counts rope/chain or all-chain rode
- Choice of feet, metres or fathoms measurement
- Logs windlass operating hours for maintenance
- Easy calibration
- Electronic diagnostics for troubleshooting installation
- Auto stop and docking alarm when the anchor is close to
docking
- Two speed operation
|
AA730 Handheld Cable Remote 
Kit includes one handheld console
unit with cradle,
one base station, a deck socket with 2m lead,
a socket sealing cap, one sensor, 2 magnets, screws for the
cradle and socket, installation and operation instructions.

AA703 Base Station
|
| |
AA730 |
| Current
Consumption |
50mA |
| Power
Supply |
12V
or 24V DC |
| Temperature
Range |
23°F
to 140°F (-5°C to 60°C) |
| Output
Maximum Current Draw |
12V
DC: 3.5A 24V DC: 3.5A |
| Output
Minimum Current Draw |
12V
DC: 10mA 24V DC: 20mA
When connecting to solid stage switching or other low current
windlass drive, a PLC or AC variable frequency drive, a dummy
resistor load may be required |
| IP
Rating |
IP67 |
| Outputs |
6 |
| Rode
- Chain Only |
Stainless
or galvanised steel |
| Rode
- Rope and Chain |
Must
have a minimum of 10ft (3m) of chain. Chain must be galvanised
steel. Rope should be a good quality nylon anchor rope. Type 66
or equivalent |
| EMC/Protection/CE |
EN60945 |
| For
DC windlasses a dual direction solenoid is required |